Abstract
Background Certified Nursing Assistants (CNAs) frequently wear gloves when they care for patients in standard precautions. If CNAs use gloves inappropriately, they may spread pathogens to patients and the environment, potentially leading to health care–associated infections (HAIs). Methods Using a descriptive structured observational design, we examined the degree of inappropriate health care personnel glove use in a random sample of 74 CNAs performing toileting and perineal care at 1 long-term care facility. Results During the 74 patient care events, CNAs wore gloves for 80.2% (1,774/2,213) of the touch points, failing to change gloves at 66.4% (225/339) of glove change points. CNAs changed gloves a median of 2.0 times per patient care event. A median of 1.0 change occurred at a change point. CNAs failed to change their gloves at a glove change point a median of 2.5 times per patient care event. Most (61/74; 82.4%) patient care events had >1 contaminated touch point. Over 44% (782/1,774) of the gloved touch points were defined as contaminated for a median of 8.0 contaminated glove touch points per patient care event. All contaminated touches were with gloved hands (P
Author supplied keywords
Cite
CITATION STYLE
Burdsall, D. P., Gardner, S. E., Cox, T., Schweizer, M., Culp, K. R., Steelman, V. M., & Herwaldt, L. A. (2017). Exploring inappropriate certified nursing assistant glove use in long-term care. American Journal of Infection Control, 45(9), 940–945. https://doi.org/10.1016/j.ajic.2017.02.017