Comparing outcomes from tailored meta-analysis with outcomes from a setting specific test accuracy study using routine data of faecal calprotectin testing for inflammatory bowel disease

0Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Meta-analyses of test accuracy studies may provide estimates that are highly improbable in clinical practice. Tailored meta-analysis produces plausible estimates for the accuracy of a test within a specific setting by tailoring the selection of included studies compatible with a specific setting using information from the target setting. The aim of this study was to validate the tailored meta-analysis approach by comparing outcomes from tailored meta-analysis with outcomes from a setting specific test accuracy study. Methods: A retrospective cohort study of primary care electronic health records provided setting-specific data on the test positive rate and disease prevalence. This was used to tailor the study selection from a review of faecal calprotectin testing for inflammatory bowel disease for meta-analysis using the binomial method and the Mahalanobis distance method. Tailored estimates were compared to estimates from a study of test accuracy in primary care using the same routine dataset. Results: Tailoring resulted in the inclusion of 3/14 (binomial method) and 9/14 (Mahalanobis distance method) studies in meta-analysis. Sensitivity and specificity from tailored meta-analysis using the binomial method were 0.87 (95% CI 0.77 to 0.94) and 0.65 (95% CI 0.60 to 0.69) and 0.98 (95% CI 0.83 to 0.999) and 0.68 (95% CI 0.65 to 0.71), respectively using the Mahalanobis distance method. The corresponding estimates for the conventional meta-analysis were 0.94 (95% CI 0.90 to 0.97) and 0.67 (95% CI 0.57 to 0.76) and for the FC test accuracy study of primary care data 0.93 (95%CI 0.89 to 0.96) and 0.61 (95% CI 0.6 to 0.63) to detect IBD at a threshold of 50 μg/g. Although the binomial method produced a plausible estimate, the tailored estimates of sensitivity and specificity were not closer to the primary study estimates than the estimates from conventional meta-analysis including all 14 studies. Conclusions: Tailored meta-analysis does not always produce estimates of sensitivity and specificity that lie closer to the estimates derived from a primary study in the setting in question. Potentially, tailored meta-analysis may be improved using a constrained model approach and this requires further investigation.

Cite

CITATION STYLE

APA

Freeman, K., Willis, B. H., Ryan, R., Taylor-Phillips, S., & Clarke, A. (2022). Comparing outcomes from tailored meta-analysis with outcomes from a setting specific test accuracy study using routine data of faecal calprotectin testing for inflammatory bowel disease. BMC Medical Research Methodology, 22(1). https://doi.org/10.1186/s12874-022-01668-9

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free