Mechanical behavior of an industrial gas turbine under fault conditions, a case history

2Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The resolve of journal bearing field problems and the full vibrational assessment of an industrial gas turbine, simple cycle rotor train, ABB's GT11N2 is presented. Three units experienced several times damage of the journal bearings on the compressor end. The analysis of the damage, including tests, indicated that insufficient jacking oil flow was the cause. The jacking concept was corrected and starting history has proven reliable operation, resulting in not one additional failure. During the same period, two last stage blades failed in one of the units damaging neighboring blades additionally. The machine tripped under the unbalance. Some auxiliary piping and the babbitt of the journal bearing was damaged. However, the rotor came to a safe stop with only some rubbing, and the turbine casing fulfilled its containment function perfectly. In order to better understand the dynamic behavior of the train, an extensive vibration measurement program was decided between Kentucky Utilities and ABB, and executed by Bently Nevada. The results proved excellent rotor balance, verified original design parameters, and no fluid induced instabilities were found. This joint effort allowed to fully assess and prove the rotor dynamic integrity of the gas turbine. © 1999 OPA (Overseas Publishers Association) N.V.

Cite

CITATION STYLE

APA

Florjancic, S. S., Lively, N., & Thomas, R. (1999). Mechanical behavior of an industrial gas turbine under fault conditions, a case history. International Journal of Rotating Machinery, 5(3), 219–230. https://doi.org/10.1155/S1023621X99000196

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free