The Impact of Changes in Corneal Back Surface Astigmatism on the Residual Astigmatic Refractive Error following Routine Uncomplicated Phacoemulsification

8Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose. To determine the significance of any association between intersessional changes in ocular residual astigmatism (RA) and astigmatism at corneal front (FSA) and back (BSA) surfaces following uneventful routine phacoemulsification. Methods. Astigmatism was evaluated by autorefractometry and subjective refraction and at both the corneal surfaces with Orbscan II™ (Bausch & Lomb) over central 3 mm and 5 mm optical zones at 1, 2, and 3 months after routine phacoemulsification in 103 patients implanted with monofocal nontoric intraocular lenses (IOLs, one eye/patient). Data were subjected to vector analysis to determine the actual change (Δ) in astigmatism (power and axis) for the refractive and Orbscan II findings. Results. The number of cases that attended where ΔRA was ≥0.50 DC between 1 and 2 months was 52 by autorefractometry and 36 by subjective refraction and between 2 and 3 months was 24 by autorefractometry and 19 by subjective refraction. Vector analysis revealed significant correlations between ΔFSA and ΔRA for data obtained by autorefractometry but not by subjective refraction. At all times, ΔBSA was greater than ΔFSA (p<0.01). Key findings for ΔBSA values over the central 3 mm zone were between (A) the sine of the axis of ΔRA (y) and sine of the axis of ΔBSA (x) for the data obtained by autorefractometry (between 1 and 2 months, y = 0.749 - 0.303x, r = 0.299, n = 52, p=0.031) and subjective refraction (between 2 and 3 months, y = 0.6614 - 0.4755x, r = 0.474, n = 19, p=0.040) and (B) ΔRA (y) and ΔBSA (x) powers between 2 and 3 months postoperatively for the data obtained by autorefractometry (ΔRA = 0.118 ΔBSA + 0.681 r = 0.467, n = 24, p=0.021) and subjective refraction (ΔRA = 0.072 ΔBSA + 0.545 r = 0.510, n = 19, p=0.026). Conclusion. Changes in the ocular residual refractive astigmatic error after implanting a monofocal nontoric IOL are associated with changes in astigmatism at the back surface of the cornea within the central optical zone.

Cite

CITATION STYLE

APA

Tutchenko, L., Patel, S., Voytsekhivskyy, O., Skovron, M., & Horak, O. (2020). The Impact of Changes in Corneal Back Surface Astigmatism on the Residual Astigmatic Refractive Error following Routine Uncomplicated Phacoemulsification. Journal of Ophthalmology, 2020. https://doi.org/10.1155/2020/7395081

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free