The paper illustrates the design and the implementation of a Fault Detection and Isolation (FDI) system to a rotary machine like a multishaft centrifugal compressor. A model-free approach, that is, the Principal Component Analysis (PCA), has been employed to solve the fault detection issue. For the fault isolation purpose structured residuals have been adopted while an adaptive threshold has been designed in order to detect and to isolate the faults. To prove the goodness of the proposed FDI system, historical data of a nitrogen centrifugal compressor employed in a refinery plant are considered. Tests results show that detection and isolation of single as well as multiple faults are successfully achieved. © 2013 Silvia M. Zanoli and Giacomo Astolfi.
CITATION STYLE
Zanoli, S. M., & Astolfi, G. (2013). Application of a fault detection and isolation system on a rotary machine. International Journal of Rotating Machinery, 2013. https://doi.org/10.1155/2013/189359