Artifact characterization of Nitinol needles in magnetic resonance imaging-guided musculoskeletal interventions at 3.0 tesla: a phantom study

4Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

PURPOSE To characterize the artifacts of an 18-gauge coaxial nickel-titanium needle using a balanced steady-state free precession sequence in magnetic resonance imaging-guided interventions at 3.0 tesla. METHODS The influence of flip angle (FA), bandwidth, matrix, slice thickness (ST), and read-out direction on needle artifact behavior was investigated for different intervention angles (IA). Artifact diameters were rated at predefined positions. Subgroup differences were assessed using Bonferroni-correct-ed non-parametric tests and correlations between continuous variables were expressed using the Bravais–Pearson coefficient. Interrater reliability was quantified using intraclass correlation coefficients (ICCs), and a contrast-enhanced target lesion to non-enhanced muscle tissue contrast ratio was quantified. RESULTS The artifact diameters decreased with an increase in FA for all IAs (P < 0.001) and with an increase in ST for IAs of 45°–90° (all P < 0.05). Tip artifacts occurred at low IAs (0°–45°) and gradually increased in size with a decrease in IA (P = 0.022). The interrater reliability was high (ICC: 0.994–0.999). The contrast-enhanced target lesion to non-enhanced muscle tissue contrast ratio presented positive correlations with increasing FAs and matrices (P < 0.001; P = 0.003) and a negative correlation with increasing STs (P = 0.007). CONCLUSION To minimize needle artifacts, it is recommended to use FAs of 40°–60°, a ST of >7 mm, and, if pos-sible, an IA of 45°–60°. The visibility of the target lesion and the needle’s artifact behavior must be weighed up against each other when choosing the ST, while higher FAs (40°–60°) and matrices (224 × 224/256 × 256) are associated with low artifacts and sufficient lesion visibility.

Cite

CITATION STYLE

APA

Schmidt, V. F., Dietrich, O., Seidensticker, M., Wildgruber, M., Erber, B., Ricke, J., & Goller, S. S. (2023). Artifact characterization of Nitinol needles in magnetic resonance imaging-guided musculoskeletal interventions at 3.0 tesla: a phantom study. Diagnostic and Interventional Radiology, 29(5), 719–732. https://doi.org/10.4274/dir.2023.232262

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free