Enhancing the energy efficiency and environmental sustainability of buildings is a significant global aim. New construction regulations are, therefore, geared specifically towards low-emission and energy-efficient projects. However, there are numerous and typically competitive priorities, such as making the most of energy usage in residential buildings. This leads to the complex topic of multi-objective optimisation. The primary aim of this research was to reduce the energy consumed for heating and cooling loads in residential buildings in Ma’an City, which is located in the Jordanian Saharan Mediterranean, a cool climate zone. This was achieved by optimising various design variables (window to wall percent, ground floor construction, local shading type, infiltration rate (ac/h), glazing type, flat roof construction, natural ventilation rate, window blind type, window shading control schedule, partition construction, site orientation and external wall construction) of the building envelope. DesignBuilder software (version 6.1) was utilised to run a sensitivity analysis (SA) for 12 design variables to evaluate their influence on both heating and cooling loads simultaneously using a regression method. The variables were divided into two groups according to their importance and a genetic algorithm (GA) was then applied to both groups. The optimum solution selected for the high-importance variables was based on minimising the heating and cooling loads. The optimum solution selected for the low-importance variables was based on the lowest summation of the heating and cooling loads. Finally, a scenario was devised (using the combined design variables of the two solutions) and simulated. The results indicate that the total energy consumption was 1186.21 kWh/year, divided into 353.03 kWh/year for the cooling load and 833.18 kWh/year for the heating load. This was compared with 9969.38 kWh/year of energy, divided into 3878.37 kWh/year for the heating load and 6091.01 kWh/year for the cooling load for the baseline building. Thus, the amount of energy saved was 88.1%, 94.2% and 78.5% for total energy consumption, cooling load and heating load, respectively. However, implementing the modifications suggested by the optimisation of the low-importance variables was not cost-effective, especially the external wall construction and partition construction, and therefore these design variables can be neglected in future studies.
CITATION STYLE
Albatayneh, A. (2021). Optimising the parameters of a building envelope in the east mediterranean Saharan, cool climate Zone. Buildings, 11(2), 1–23. https://doi.org/10.3390/buildings11020043
Mendeley helps you to discover research relevant for your work.