Abstract
The article describes determination of value of frequency-independent component of AC-DC voltage transfer difference of calculable thermal AC voltage standards developed and maintained at Silesian University Technology (SUT). According to our research, the value of this parameter is within ±0.1 μV/V with combined standard uncertainty of 0.4 μV/V. The obtained results will be used to supplement the uncertainty budgets of these standards. The proposed method can be used to determine frequency-independent component of AC-DC voltage transfer differences of thermal AC voltage standards when a quantum AC voltage standard is unavailable.
Author supplied keywords
Cite
CITATION STYLE
Grzenik, M., & Kampik, M. (2018). Determination of frequency-independent component of AC-DC transfer difference of SUT’s calculable AC voltage standards. In I2MTC 2018 - 2018 IEEE International Instrumentation and Measurement Technology Conference: Discovering New Horizons in Instrumentation and Measurement, Proceedings (pp. 1–5). Institute of Electrical and Electronics Engineers Inc. https://doi.org/10.1109/I2MTC.2018.8409621