Changeovers of vasoactive drug infusion pumps: Impact of a quality improvement program

  • L. A
  • M. C
  • O. M
  • et al.
N/ACitations
Citations of this article
4Readers
Mendeley users who have this article in their library.

Abstract

Background: Hemodynamic instability following the changeover of vasoactive infusion pump (CVIP) is a common problem in the intensive care unit. Several empiric methods are used to achieve CVIP. We hypothesized that the variation in these procedures could generate some morbidity. We sought to assess the effects of the standardization of practice, as a quality improvement program, on the CVIP-induced incidents. Materials and methods: We performed a prospective before-and-after intervention study including all adult patients with a diagnosis of cardiovascular failure who received a continuous infusion of vasoactive drugs or inotropic drugs. After a baseline preimplementation period (phase 1), a standardized 'quick change method' of CVIP using two syringe drivers was implemented in our intensive care unit (phase 2). Endpoints (rate and distribution of incidents: variations of systolic blood pressure >20 mmHg or heart rate >20 beats/min, and arrhythmias) were registered in both 3-month phases. Results: We studied a total of 913 CVIP events (phase 1, 435 events; phase 2, 478 events) from 43 patients. Patient characteristics were not significantly different among phases, with a majority of the patients having septic shock. The frequency of incidents was significantly (P < 0.0001) reduced in phase 2 (5.9%, n = 28) versus phase 1 (17.8%, n = 78). This effect was observed whichever catecholamine was used. More than 98% of incidents were blood pressure variations, with a similar distribution of the nature of incidents in both phases. Conclusion: The present study illustrates that adverse events are common following CVIP, and illustrates the positive impact of a quality improvement program to enhance inpatient safety related to this current process of care. © 2008 Argaud et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

L., A., M., C., O., M., M., S.-D., T., F., & A., G. (2007). Changeovers of vasoactive drug infusion pumps: Impact of a quality improvement program. Critical Care. L. Argaud, Hospices Civils de Lyon, Hopital Edouard Herriot, Department of Emergency and Medical Intensive Care, Lyon F-69003, France. E-mail: laurent.argaud@chu-lyon.fr: BioMed Central Ltd. Retrieved from http://ovidsp.ovid.com/ovidweb.cgi?T=JS&PAGE=reference&D=emed8&NEWS=N&AN=2008026233

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free