The characteristics of a Compton-suppressed, two-fold segmented, Clover detector have been studied in singles and add-back modes for using it in the study of heavy-ion fusion-evaporation reactions. The measurements have been performed with standard sources of 152Eu, 60Co and in-beam γ-rays from the fusion-evaporation reaction 28Si on 27Al at Elab = 100 MeV. Reduction in γ-ray Doppler broadenings due to the two-fold segmentation is demonstrated through in-beam data. © 2003 Elsevier Science B.V. All rights reserved.

Cite

CITATION STYLE

APA

Nara Singh, B. S., Jain, H. C., Joshi, P. K., Lakshmi, S., Mazumdar, I., Nagaraj, S., & Naidu, B. S. (2003). Characteristics of a two-fold segmented Clover detector. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 506(3), 238–249. https://doi.org/10.1016/S0168-9002(03)01358-5