Partial Nephrectomy in a Patient with a Left Ventricular Assist Device

  • Manger J
  • Kern J
  • Krupski T
N/ACitations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Left ventricular assist device (LVAD) use has increased as a bridge to heart transplant as well as destination therapy in patients with severe heart failure. Presence of LVAD is not a contraindication to noncardiac surgery but does present special challenges to the surgical, anesthesia, and cardiac teams. We present the case of a 40-year-old woman with idiopathic cardiomyopathy necessitating LVAD who underwent left partial nephrectomy for a renal mass. She had undergone three nondiagnostic percutaneous image-guided biopsies. Left partial nephrectomy was performed. Perioperative care was without incident due to careful oversight by a multidisciplinary team. Pathology revealed high-grade clear cell renal cell carcinoma (RCC) with negative margins. Polytetrafluoroethylene (PTFE) bolsters were misidentified six months postoperatively on computed tomography (CT) at an outside institution as a retained laparotomy sponge. This is, to our knowledge, the first report of a partial nephrectomy performed in a patient with LVAD.

Cite

CITATION STYLE

APA

Manger, J. P., Kern, J. A., & Krupski, T. L. (2011). Partial Nephrectomy in a Patient with a Left Ventricular Assist Device. Case Reports in Urology, 2011, 1–5. https://doi.org/10.1155/2011/526903