Diagnostic performance and safety of NMK36 (trans-1-amino-3-[18F]fluorocyclobutanecarboxylic acid)-PET/CT in primary prostate cancer: Multicenter Phase IIb clinical trial

42Citations
Citations of this article
49Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective: We performed a multicenter Phase IIb clinical trial of NMK36, a novel amino acid analog for positron emission tomography containing trans-1-amino-3-[18F]fluorocyclobutanecarboxylic acid, to evaluate its safety and diagnostic performance for primary prostate cancer. Methods: Sixty-eight subjects with primary prostate cancer scheduled for radical prostatectomy or hormone therapy underwent whole-body positron emission tomography/computed tomography after injection of NMK36. The diagnostic performances of NMK36-positron emission tomography/ computed tomography were evaluated for (i) regional lymph node metastasis: comparison with contrast- enhanced computed tomography under setting reference standard (histopathology or 6-month follow-up), (ii) bone metastasis: concordance rate with conventional imaging (combination of bone scintigraphy and contrast-enhanced computed tomography) and (iii) primary lesion: comparison with histopathological findings. Results: The accuracy ofNMK36-positron emission tomography/computed tomography and contrastenhanced computed tomography for regional lymph node metastasis were 85.5 and 87.3%, respectively. NMK36-positron emission tomography/computed tomography showed positive findings for regional lymph nodes with short-axis diameters of 5-9 mm at 23 regions in 13 patients of hormone therapy cohort, but they were not confirmed with reference standard in this study. The concordance rate of NMK36-positron emission tomography/computed tomography with conventional imaging for bone metastases was 83.3%, and seven patients had positive findings only by NMK36-positron emission tomography/computed tomography. The sensitivity and specificity of NMK36-positron emission tomography/computed tomography for primary lesion in six-segment analysis was 92.5 and 90.1%, respectively. Seven of non-serious adverse events were observed in six patients. Conclusions: This study showed the comparable diagnostic performance of NMK36-positron emission tomography/computed tomography compared with conventional imaging. Some lesions of lymph node and bone were positive solely by NMK36-positron emission tomography/computed tomography, which needs to be confirmed with reference standard in future study to evaluate the usefulness of NMK36-positron emission tomography/computed tomography in staging prostate cancer.

Cite

CITATION STYLE

APA

Suzuki, H., Inoue, Y., Fujimoto, H., Yonese, J., Tanabe, K., Fukasawa, S., … Otaka, A. (2016). Diagnostic performance and safety of NMK36 (trans-1-amino-3-[18F]fluorocyclobutanecarboxylic acid)-PET/CT in primary prostate cancer: Multicenter Phase IIb clinical trial. Japanese Journal of Clinical Oncology, 46(2), 152–162. https://doi.org/10.1093/jjco/hyv181

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free