Cone-beam CT versus multidetector CT in postoperative cochlear implant imaging: evaluation of image quality and radiation dose

23Citations
Citations of this article
34Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUND AND PURPOSE: Cone-beam CT is being increasingly used in head and neck imaging. We compared cone-beam CT with multidetector CT to assess postoperative implant placement and delineate finer anatomic structures, image quality, and radiation dose used. MATERIALS AND METHODS: This retrospective multicenter study included 51 patients with cochlear implants and postoperative imaging via temporal bone cone-beam CT (n ¼ 32 ears) or multidetector CT (n ¼ 19 ears) between 2012 and 2017. We evaluated the visualization quality of single electrode contacts, the scalar position of the electrodes, cochlear walls, mastoid facial canal, metallic artifacts (using a 4-level visual score), and the ability to measure the insertion angle of the electrodes. The signal-to-noise ratio and radiation dose were also evaluated. RESULTS: Cone-beam CT was more sensitive for visualizing the scalar position of the electrodes (P ¼ .046), cochlear outer wall (P ¼ .001), single electrode contacts (P, .001), and osseous spiral lamina (P ¼ .004) and had fewer metallic artifacts (P, .001). However, there were no significant differences between both methods in visualization of the modiolus (P ¼ .37), cochlear inner wall (P . .99), and mastoid facial canal wall (P ¼ .07) and the ability to measure the insertion angle of the electrodes (P . .99). The cone-beam CT group had significantly lower dose-length product (P, .001), but multidetector CT showed a higher signal-to-noise ratio in both bone and air (P ¼ .22 and P ¼ .001). CONCLUSIONS: Cone-beam CT in patients with cochlear implants provides images with higher spatial resolution and fewer metallic artifacts than multidetector CT at a relatively lower radiation dose.

Cite

CITATION STYLE

APA

Helal, R. A., Jacob, R., Elshinnawy, M. A., Othman, A. I., Al-Dhamari, I. M., Paulus, D. W., & Abdelaziz, T. T. (2021). Cone-beam CT versus multidetector CT in postoperative cochlear implant imaging: evaluation of image quality and radiation dose. American Journal of Neuroradiology, 42(2), 362–367. https://doi.org/10.3174/ajnr.A6894

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free