Neurally adjusted ventilatory assist increases respiratory variability and complexity in acute respiratory failure

86Citations
Citations of this article
74Readers
Mendeley users who have this article in their library.

Abstract

Background: Neurally adjusted ventilatory assist (NAVA) is a partial ventilatory support mode where positive pressure is provided in relation to diaphragmatic electrical activity (EAdi). Central inspiratory activity is normally not monotonous, but it demonstrates short-term variability and complexity. The authors reasoned that NAVA should produce a more "natural" or variable breathing pattern than other modes. This study compared respiratory variability and complexity during pressure support ventilation (PSV) and NAVA. Methods: Flow and EAdi were recorded during routine PSV (tidal volume ∼6-8 ml/kg) and four NAVA levels (1-4 cm H2O/μVEAdi) in 12 intubated patients. Breath-by-breath variability of flow and EAdi-related variables was quantified by the coefficient of variation (CV) and autocorrelation analysis. Complexity of flow and EAdi was described using noise titration, largest Lyapunov exponent, Kolmogorov-Sinai entropy, and three-dimensional phase portraits. Results: Switching from PSV to NAVA increased the CV and decreased the autocorrelation for most flow-related variables in a dose-dependent manner (P < 0.05, partial η for the CV of mean inspiratory flow 0.642). The changes were less marked for EAdi. A positive noise limit was consistently found for flow and EAdi. Largest Lyapunov exponent and Kolmogorov-Sinai entropy for flow were greater during NAVA than PSV and increased with NAVA level (P < 0.05, partial η 0.334 and 0.312, respectively). Largest Lyapunov exponent and Kolmogorov-Sinai entropy for EAdi were not influenced by ventilator mode. Conclusions: Compared with PSV, NAVA increases the breathing pattern variability and complexity of flow, whereas the complexity of EAdi is unchanged. Whether this improves clinical outcomes remains to be determined. Copyright © 2010, the American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins.

Cite

CITATION STYLE

APA

Schmidt, M., Demoule, A., Cracco, C., Gharbi, A., Fiamma, M. N., Straus, C., … Similowski, T. (2010). Neurally adjusted ventilatory assist increases respiratory variability and complexity in acute respiratory failure. Anesthesiology, 112(3), 670–681. https://doi.org/10.1097/ALN.0b013e3181cea375

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free