Effect of PRID-Delta devices associated with shortened estrus synchronization protocols on estrous response and fertility in dairy cows

5Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

Abstract

This study evaluated the effect of a once-used progesterone (P4) intravaginal device (PRID) associated with four different shortened P4-based estrus synchronization (ES) protocols on estrous response (ER) and pregnancy per AI (P/AI) in cyclic and acyclic lactating dairy cows. Cows (n=465) were randomly assigned to one of the following protocols: 1) 2PGG, cows were given a PRID-Delta and 100 μg GnRH i.m. at PRID insertion (day 0). The PRID was left for 5 d, and 25 mg of dinoprost (PGF2α) i.m. given twice at PRID removal and 24 h later; 2) 2PGGe, same treatments as 2PGG plus 500 IU of eCG i.m. at PRID removal; 3) 2PGe, same treatments as 2PGGe, except GnRH was not given at PRID insertion; 4) PGe, same treatments as 2PGe, except PGF was only given at PRID removal. A total of 258 cows received a new PRID-Delta containing 1.55 g of P4, whereas 207 cows received a once-used PRID. Estrus was determined from P4 device removal until 96 h after using an automated heat detection system. Cows in estrus were given a second GnRH at AI and those without signs of estrus by 96 h after PRID removal were given GnRH and timed-AI (TA I). All inseminations were performed by one technician with commercially available frozen-thawed semen. Ultrasonography was performed at initiation of protocol and 28-34 days post AI to determine cyclicity and pregnancy status, respectively. Cows receiving once-used P4 devices had greater ER than cows receiving a new device (59.9 vs. 50.0; P=0.029), but P/AI did not differ between P4 devices, respectively (P>0.1; 40.6 vs 40.7%). Cyclic cows were less likely to display estrus than acyclic cows by a factor of 0.66 (P=0.036). Cows subjected to the 2PGe (2.41; P<0.01) protocol were more likely to display estrus than cows subjected to the 2PGG, whereas cows subjected to the PGe protocol did not differ (0.94; P=0.8) from those in the 2PGG group. Despite differences in ER, neither cyclicity nor estrus synchronization protocol affected P/AI (overall 40.6%). In summary, cyclic cows, those given a new P4 device and those subjected to either 2PGG or PGe protocol had reduced ER. However, all the factors examined had no significant effect on P/AI. All the estrus synchronization protocols resulted in acceptable fertility.

Cite

CITATION STYLE

APA

López-Helguera, I., López-Gatius, F., Garcia-Ispierto, I., Serrano-Perez, B., & Colazo, M. G. (2017). Effect of PRID-Delta devices associated with shortened estrus synchronization protocols on estrous response and fertility in dairy cows. Annals of Animal Science, 17(3), 757–770. https://doi.org/10.1515/aoas-2016-0083

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free