Rebound kinetics of β2-microglobulin after hemodialysis

63Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background. Evaluation of [β2-microglobulin (β2m) removal during hemodialysis using predialysis and immediate postdialysis plasma concentrations is only valid in the absence of postdialysis rebound. Postdialysis rebound of β2m has not been studied extensively, and its importance in the determination of β2m clearance is unknown. Methods. We evaluated the kinetics of urea and β2m in a crossover study of 10 chronic hemodialysis patients using dialyzers with similar urea mass transfer-area coefficients containing either low-flux cellulose acetate or high-flux cellulose triacetate membranes. Kinetics were examined during and following a 210 minute treatment by measuring plasma concentrations predialysis at regular intervals during therapy and at 0, 2, 10, 20, 30, and 60 minutes postdialysis. Clearances of urea and β2m were also determined directly from the arterial and venous concentration differences across the dialyzer at 60 minutes after starting dialysis. Results. By design, urea removal was similar for both low-flux and high-flux dialyzers as assessed by the urea reduction ratio and Kt/V. Postdialysis urea rebound was similar for low- and high-flux dialyzers; the rebound in the plasma urea nitrogen concentration (expressed as a percentage of the intradialytic decrease in plasma concentration) was 9.2 ± 1.9% (mean SEM) at 30 minutes postdialysis and 13.0 ± 1.4% at 60 minutes postdialysis for a single pool urea Kt/V of 1.16 ± 0.05. The plasma β2m concentration increased by 11.1 ± 3.0% during the treatment using the low-flux dialyzer but decreased by 27.1 4.0% during the treatment using the high-flux dialyzer. When using the high-flux dialyzer, the rebound of β2m was 44.8 ± 21.4% at 30 minute postdialysis and 45.9 ± 15.9% at 60 minutes postdialysis. The clearance of β2m for the high-flux dialyzer calculated from predialysis and immediate postdialysis plasma concentrations using a single-compartment model (28.2 ± 4.4 ml/min) was higher (P < 0.05) than that determined directly across the dialyzer (18.3 ± 2.0 ml/min). If either the 30- or 60-minute postdialysis plasma β2m concentration was used instead, the calculated β2m clearance (16.5 ± 4.8 ml/min or 15.6 ± 2.8 ml/min, respectively) was similar to that determined directly across the dialyzer. Conclusions. Postdialysis rebound of β2m when using high-flux dialyzers is substantial; neglecting postdialysis rebound results in an overestimation of β2m clearance when calculated using a single-compartment model.

Cite

CITATION STYLE

APA

Leypoldt, J. K., Cheung, A. K., & Barry Deeter, R. (1999). Rebound kinetics of β2-microglobulin after hemodialysis. In Kidney International (Vol. 56, pp. 1571–1577). Nature Publishing Group. https://doi.org/10.1046/j.1523-1755.1999.00669.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free