Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: A comparative study with technical considerations

17Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

Abstract

Background: The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study presents a comparison of radiation doses, calculated for fluoroscopy and CT-guided SI joint injections in standard and low-dose protocol and presents the technical possibility of CT-guidance with maximum radiation dose reduction to levels of fluoroscopic-guidance for a precise intra-articular injection technique. Objective: To evaluate the possibility of dose reduction in CT-guided sacroiliac joint injections to pulsed-fluoroscopy-guidance levels and to compare the doses of pulsed-fluoroscopy-, CT-guidance, and low-dose CT-guidance for intra-articular SI joint injections. Study design: Comparative study with technical considerations. Methods: A total of 30 CT-guided intra-articular SI joint injections were performed in January 2012 in a developed low-dose mode and the radiation doses were calculated. They were compared to 30 pulsed-fluoroscopy-guided SI joint injections, which were performed in the month before, and to five injections, performed in standard CT-guided biopsy mode for spinal interventions. The statistical significance was calculated with the SPSS software using the Mann-Whitney U-Test. Technical details and anatomical considerations were provided. Results: A significant dose reduction of average 94.01% was achieved using the low-dose protocol for CT-guided SI joint injections. The radiation dose could be approximated to pulsed-fluoroscopy-guidance levels. Conclusion: Radiation dose of CT-guided SI joint injections can be decreased to levels of pulsed fluoroscopy with a precise intra-articular needle placement using the low-dose protocol. The technique is simple to perform, fast, and reproducible. © 2012 Artner et al, publisher and licensee Dove Medical Press Ltd.

Cite

CITATION STYLE

APA

Artner, J., Cakir, B., Reichel, H., & Lattig, F. (2012). Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: A comparative study with technical considerations. Journal of Pain Research, 5, 265–269. https://doi.org/10.2147/JPR.S34429

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free