Tight focusing with a binary microaxicon

  • Kotlyar V
  • Stafeev S
  • O’Faolain L
  • et al.
34Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

Abstract

Using a near-field scanning microscope (NT-MDT) with a 100 nm aperture cantilever held 1 μm apart from a microaxicon of diameter 14 μm and period 800 nm, we measure a focal spot resulting from the illumination by a linearly polarized laser light of wavelength λ=532 nm, with its FWHM being equal to 0.58λ, and the depth of focus being 5.6λ. The rms deviation of the focal spot intensity from the calculated value is 6%. The focus intensity is five times larger than the maximal illumination beam intensity.

Cite

CITATION STYLE

APA

Kotlyar, V. V., Stafeev, S. S., O’Faolain, L., & Soifer, V. A. (2011). Tight focusing with a binary microaxicon. Optics Letters, 36(16), 3100. https://doi.org/10.1364/ol.36.003100