Measurement of 1,5-anhydroglucitol in blood and saliva: From non-targeted metabolomics to biochemical assay

39Citations
Citations of this article
58Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Diabetes testing using saliva, rather than blood and urine, could facilitate diabetes screening in public spaces. We previously identified 1,5-anhydro-d-glucitol (1,5-AG) in saliva as a diabetes biomarker. The Glycomark™ assay kit is FDA approved for 1,5-AG measurement in blood. Here we evaluated its applicability for 1,5-AG quantification in saliva. Methods: Using pooled saliva samples, we validated Glycomark™ assay use with a RX Daytona+ clinical chemistry analyser. We then used this set-up to analyse 82 paired blood and saliva samples from a diabetes case-control study, for which broad mass spectrometry-based characterization of the blood and saliva metabolome was also available. Osmolality was measured to account for potential variability in saliva samples. Results: The technical variability of the read-outs for the pooled saliva samples (CV = 2.05 %) was comparable to that obtained with manufacturer-provided blood surrogate quality controls (CV = 1.38-1.8 %). We found a high correlation between Glycomark assay and mass spectrometry measurements of serum 1,5-AG (r2 = 0.902), showing reproducibility of the non-targeted metabolomics results. The significant correlation between the osmolality measurements performed at two independent platforms with the time interval of 2 years (r2 = 0.887), also indicates the sample integrity. The assay read-out for saliva was not correlated with the mass spectrometry-based 1,5-AG saliva measurements. Comparison with the full saliva metabolome revealed a high correlation of the saliva assay read-outs with galactose. Conclusions: Glycomark™ assay read-outs for saliva were stable and replicable. However, the signal was dominated by galactose, which is biochemically similar to 1,5-AG and absent in blood. Adapting the 1,5-AG kit for saliva analysis will require enzymatic depletion of galactose. This should be feasible, since the assay already includes a similar step for glucose depletion from blood samples.

Cite

CITATION STYLE

APA

Halama, A., Kulinski, M., Kader, S. A., Satheesh, N. J., Abou-Samra, A. B., Suhre, K., & Mohammad, R. M. (2016). Measurement of 1,5-anhydroglucitol in blood and saliva: From non-targeted metabolomics to biochemical assay. Journal of Translational Medicine, 14(1). https://doi.org/10.1186/s12967-016-0897-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free