Evaluation of microflow digital imaging particle analysis for sub-visible particles formulated with an opaque vaccine adjuvant

14Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

Abstract

Microflow digital imaging (MDI) has become a widely accepted method for assessing subvisible particles in pharmaceutical formulations however, to date; no data have been presented on the utility of this methodology when formulations include opaque vaccine adjuvants. This study evaluates the ability of MDI to assess sub-visible particles under these conditions. A Fluid Imaging Technologies Inc. FlowCAM® instrument was used to assess a number of sub-visible particle types in solution with increasing concentrations of Adda-Vax™, a nanoscale squalene-based adjuvant. With the objective (10X) used and the limitations of the sensor resolution, the instrument was incapable of distinguishing between subvisible particles and AddaVax™droplets at particle sizes less than 5 μm. The instrument was capable of imaging all particle types assessed (polystyrene beads, borosilicate glass, cellulose, polyethylene protein aggregate mimics, and lysozyme protein aggregates) at sizes greater than 5 μm in concentrations of AddaVax™up to 50% (vol:vol). Reduced edge gradients and a decrease in measured particle sizes were noted as adjuvant concentrations increased. No significant changes in particle counts were observed for polystyrene particle standards and lysozyme protein aggregates, however significant reductions in particle counts were observed for borosilicate (80% of original) and cellulose (92% of original) particles. This reduction in particle counts may be due to the opaque adjuvant masking translucent particles present in borosilicate and cellulose samples. Although the results suggest that the utility of MDI for assessing sub-visible particles in high concentrations of adjuvant may be highly dependent on particle morphology, we believe that further investigation of this methodology to assess sub-visible particles in challenging formulations is warranted.

Cite

CITATION STYLE

APA

Frahm, G. E., Pochopsky, A. W. T., Clarke, T. M., & Johnston, M. J. W. (2016). Evaluation of microflow digital imaging particle analysis for sub-visible particles formulated with an opaque vaccine adjuvant. PLoS ONE, 11(2). https://doi.org/10.1371/journal.pone.0150229

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free