Atmospheric dispersion modeling and radiation dose calculations have been performed for a hypothetical AP1000 SGTR accident by HotSpot code 3.03. TEDE, the respiratory time-integrated air concentration, and the ground deposition are calculated for various atmospheric stability classes, Pasquill stability categories A-F with site-specific averaged meteorological conditions. The results indicate that the maximum plume centerline ground deposition value of 1.2E+2 kBq/m2 occurred at about 1.4 km and the maximum TEDE value of 1.41E-05 Sv occurred at 1.4 km from the reactor. It is still far below the annual regulatory limits of 1 mSv for the public as set in IAEA Safety Report Series number 115. The released radionuclides might be transported to long distances but will not have any harmful effect on the public.

Cite

CITATION STYLE

APA

Cao, B., Zheng, J., & Chen, Y. (2016). Radiation dose calculations for a hypothetical accident in xianning nuclear power plant. Science and Technology of Nuclear Installations, 2016. https://doi.org/10.1155/2016/3105878