Prospective clinical trial of upright image-guided proton therapy for locally recurrent head and neck and brain malignancies

4Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: The advent of commercially available vertical CT systems has renewed interest in gantry-less proton therapy (PT), in which patients are treated in an upright position using a fixed beamline and robotic positioning. This study evaluates the feasibility, safety, and preliminary efficacy of novel gantry-less image-guided adaptive PT (IGAPT) for recurrent head and neck (HN) and brain malignancies. Materials and methods: A planned interim analysis was performed on 20 adult patients with recurrent HN (80 %) and brain (20 %) cancers, median age 62 years, with Eastern Cooperative Oncology Group (ECOG) performance status ≤2. Patients underwent upright and supine imaging and simulation, followed by treatment planning comparing upright PT to conventional supine intensity-modulated radiotherapy (IMRT). Dosimetric analyses focused on organ-at-risk (OAR) sparing and target coverage. Toxicities were assessed prospectively every three months using the Common Terminology Criteria for Adverse Events (CTCAE). Results: Gantry-less PT demonstrated significant dosimetric advantages over photon IMRT, including reduced doses to critical OARs including brainstem (6 Gy(RBE) vs. 19.1 Gy; p < 0.001) and spinal cord (12.5 Gy(RBE) vs. 18.3 Gy; p < 0.006). At 3-month follow-up (n = 14), a complete response was observed in 64.3 % of evaluable patients and a partial response in 21.4 %. Most toxicities were mild-to-moderate (grades 1–2), primarily dermatitis (55 %), fatigue (45 %), and mucositis (31.3 %). Grade 3 toxicities occurred in four patients (20 %). There were no device-related deaths. Conclusions: This first clinical evaluation of a novel gantry-less IGAPT system confirms its feasibility, safety, and promising efficacy for recurrent HN and brain cancer, with superior dosimetry and high local control rates. Its cost-effective design may improve global access to the IGAPT.

Cite

CITATION STYLE

APA

Blumenfeld, P., Pryanichnikov, A., Hillman, Y., Wajnryt, E., Berger, A., Winograd, S., … Popovtzer, A. (2025). Prospective clinical trial of upright image-guided proton therapy for locally recurrent head and neck and brain malignancies. Radiotherapy and Oncology, 211. https://doi.org/10.1016/j.radonc.2025.111097

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free