Diagnostic performance of on-site computed CT-fractional flow reserve based on fluid structure interactions: Comparison with invasive fractional flow reserve and instantaneous wave-free ratio

40Citations
Citations of this article
37Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims We evaluated diagnostic accuracy of CT-fractional flow reserve (CT-FFR) computed on-site with a new vendor workstation, against invasive FFR as the reference standard. Methods and results Retrospective analyses compared CT-FFR of 104 vessels with 30-90% diameter stenosis in 75 patients imaged using single-rotation 320 detector-row coronary CT angiography (CCTA) with invasive FFR performed within 90 days. Prospective ECG-gated CCTA included exposure of 70-99% of the R-R interval. CT-FFR was computed on-site within the same physical space as the CT scanner and reading room. The diagnostic accuracy of CCTA >50% and CT-FFR ≤0.8 to detect hemodynamically significant stenosis, defined as FFR ≤0.8, was determined, as was the correlation of CT-FFR to FFR and instantaneous wave-free ratio (iFR). Forty-four vessels (42.3%) had an invasive FFR ≤0.8. The sensitivity, specificity, positive, and negative predictive value of CT-FFR ≤0.8 vs. CCTA >50% to detect hemodynamically significant stenosis defined as FFR ≤0.8 were 90.9% vs. 70.5%, 78.3% vs. 43.3%, 75.5% vs. 47.7%, and 92.2% vs. 66.7%, respectively. Area under the curve of CT-FFR was significantly higher than CCTA >50% [0.85, 95% confidence interval (CI): 0.76-0.91 vs. 0.57, 95% CI: 0.47-0.67; P < 0.0001]. The correlation coefficient between CT-FFR and iFR was r = 0.62 (95% CI: 0.40-0.77, P < 0.0001) and that between CT-FFR and invasive FFR was r = 0.52 (95% CI: 0.28-0.70, P = 0.0001). CT-FFR inter- and intra-observer correlations were excellent (r = 0.83 and r = 0.82, respectively). Conclusion Locally computed CT-FFR based on fluid structure interaction has excellent diagnostic accuracy to detect a significant FFR ≤0.8 compared with conventional CCTA and high reproducibility.

Cite

CITATION STYLE

APA

Fujimoto, S., Kawasaki, T., Kumamaru, K. K., Kawaguchi, Y., Dohi, T., Okonogi, T., … Daida, H. (2019). Diagnostic performance of on-site computed CT-fractional flow reserve based on fluid structure interactions: Comparison with invasive fractional flow reserve and instantaneous wave-free ratio. European Heart Journal Cardiovascular Imaging, 20(3), 343–352. https://doi.org/10.1093/ehjci/jey104

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free