Recurrent symphysitis culminating in pelvic ring fracture after hyperextended transurethral prostate resection and vaporization with symphysis erosion: a case report

4Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Short-term and long-term complications of transurethral prostate resection can be different in nature. Capsule perforation and subsequent fistulation after resection and electrovaporization is seldom reported in the literature. Case presentation: Here we report the case of a 79-year-old caucasian man with capsule perforation after transurethral prostate resection and electrovaporization resulting in a severe and recurrent symphysitis and subsequent pelvic ring fracture. The bladder-symphysis fistulation was surgically removed and additional orthopedic surgery could be avoided after definitely solving the urological problem. Conclusions: Urologists should be aware of rare complications after transurethral resection and electrovaporization of the prostate.

Cite

CITATION STYLE

APA

Gerullis, H., Eitzen, A., Uphoff, J., Daaboul, F., Chavan, A., Ermert, L., … Winter, A. (2017). Recurrent symphysitis culminating in pelvic ring fracture after hyperextended transurethral prostate resection and vaporization with symphysis erosion: a case report. Journal of Medical Case Reports, 11(1). https://doi.org/10.1186/s13256-017-1292-5