Abstract
The paper presents the analytical and experimental analysis of heat transfer for the finned tube coil heat exchanger immersed in thermal storage tank. The tank is equipped with three helical-shaped heating coils and cylindrical- shaped stratification device. Two coils, upper and lower, use the water as a heating medium. The third, double wall heat exchanger coil, located at the bottom head on the tank is filled by the refrigerant (freon). Calculations of thermal power of water coil were made. Correlations of heat transfer coefficients in curved tubes were applied. In order to verify the analytical calculations the experimental studies of heat transfer characteristic for coil heat exchanger were performed.
Cite
CITATION STYLE
Smusz, R. (2016). Analytical and experimental analysis of tube coil heat exchanger. In Journal of Physics: Conference Series (Vol. 745). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/745/3/032083