Reliability of IMU-Derived Gait Parameters in Foot Drop Patients

2Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

Abstract

Foot drop is a deficit in foot dorsiflexion causing difficulties in walking. Passive ankle-foot orthoses are external devices used to support the drop foot improving gait functions. Foot drop deficits and therapeutic effects of AFO can be highlighted using gait analysis. This study reports values of the major spatiotemporal gait parameters assessed using wearable inertial sensors on a group of 25 subjects suffering from unilateral foot drop. Collected data were used to assess the test-retest reliability by means of Intraclass Correlation Coefficient and Minimum Detectable Change. Excellent test-retest reliability was found for all the parameters in all walking conditions. The analysis of Minimum Detectable Change identified the gait phases duration and the cadence as the most appropriate parameters to detect changes or improvements in subject gait after rehabilitation or specific treatment.

Cite

CITATION STYLE

APA

Coccia, A., Amitrano, F., Pagano, G., Biancardi, A., Tombolini, G., & D’Addio, G. (2023). Reliability of IMU-Derived Gait Parameters in Foot Drop Patients. In Studies in Health Technology and Informatics (Vol. 302, pp. 962–966). IOS Press BV. https://doi.org/10.3233/SHTI230318

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free