Abstract
In this paper, flow characteristics of a two-phase loop thermosyphon under verti-cal reciprocating vibration are visually investigated with N-pentane as the work-ing fluid. The tests are performed for a heating power range of 20 W to 40 W, the filling ratio of 30% to 70%, and a 30 m/s2, 35 Hz vertical reciprocating vibration. The effect of vertical vibration on flow characteristics of the two-phase loop thermosyphon is investigated by comparing the obtained results with those ac-quired in static, thereby providing a basis for explaining the heat transfer process of two-phase loop thermosyphon under vibration. The results indicate that verti-cal vibration promotes the rupture of a liquid plug and the transformation of the plug flow to annular flow or wavy flow. Furthermore, the vertical vibration does not change the distribution law of liquid flow velocity in the two-phase loop thermosyphon. However, it will reduce the overheating and flow velocity in the two-phase loop thermosyphon at the start-up. With an increase in the heating power, the influence of vertical vibration on liquid flow velocity is reduced due to continuous disturbance of the working medium in the two-phase loop thermosy-phon.
Author supplied keywords
Cite
CITATION STYLE
Wang, Z., Li, F., & Cha, M. (2022). EXPERIMENTAL INVESTIGATION OF FLOW CHARACTERISTICS IN A VERTICAL VIBRATION TWO-PHASE LOOP THERMOSYPHON. Thermal Science, 26(5), 4367–4376. https://doi.org/10.2298/TSCI211023014W
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.