Perkiraan Tegangan Lewat Denyar Isolator Tegangan Menengah 20 kV Keramik dan Resin Epoksi berdasarkan Data Arus Bocor

  • Yandri V
  • Herisajani H
  • Fitriadi F
N/ACitations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

This paper explains the research results of leakage current data and estimation of flashover voltage on ceramics and epoxy resin as 20 kV outdoor insulator in a chamber with tropical climate conditions. The waveform of leakage current (LC) was measured using a digital oscilloscope. The digital data was transferred to a personal computer using a RS-232 cable. The digital data was analyzed using Fast Fourier Transform. The result showed that LC was affected by various environment conditions like temperature, humidity and pollution. LC of ceramics insulator was higher than epoxy resin insulator in low temperature, high humidity and high pollution condition.

Cite

CITATION STYLE

APA

Yandri, V. R., Herisajani, H., & Fitriadi, F. (2019). Perkiraan Tegangan Lewat Denyar Isolator Tegangan Menengah 20 kV Keramik dan Resin Epoksi berdasarkan Data Arus Bocor. Elektron : Jurnal Ilmiah, 11(1), 34–38. https://doi.org/10.30630/eji.11.1.98