Total Hip Arthroplasty with Cemented Dual Mobility Cup into a Fully Porous Multihole Cup with Variable Angle Locking Screws for Acetabular Fractures in the Frail Elderly

7Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: The purpose was to examine the clinical and radiological outcomes after surgical treatment of acetabu-lar fractures with total hip arthroplasty with a dual mobility cup cemented into a porous multihole cup in the pop-ulation of frail elderly patients. Materials and Methods: A retrospective review of 16 patients who underwent surgery (mean age, 76.7 years) with a mean follow-up period of 36.9 months was conducted. Following surgery, patients underwent postoperative follow-up at six weeks, three, six, and 12 months and clinical and radiological examinations were per-formed. Results: Classification of fractures was based on the Letournel classification. Following surgery, all patients were allowed weight-bearing as tolerated immediately postoperative. Fourteen patients showed maintenance of preoperative mobility status at one year. The mean Harris hip score was 64.8 (range, 34.7-82.8) and 80.0 (range, 60.8-93.8) at three months and one year, respectively. The mortality rate was 12.5% at one year (2/16). Complications included heterotopic ossification (2/16), deep venous thrombosis (1/16), heamatoma (1/16), and femoral revision due to a Vancouver B2 fracture (1/16). No case of deep infection, dislocation, or implant loosening was reported. Conclusion: Total hip arthroplasty using a dual mobility cup cemented into a porous multihole cup with locking screws resulted in a stable construct with a capacity for immediate weight-bearing as tolerated with rapid relief of pain. The findings of this study suggest that this procedure can be regarded as a safe method that has shown promising clinical and radiological outcomes for treatment of patients with medical frailty.

Cite

CITATION STYLE

APA

van den Broek, M., & Govaers, K. (2023). Total Hip Arthroplasty with Cemented Dual Mobility Cup into a Fully Porous Multihole Cup with Variable Angle Locking Screws for Acetabular Fractures in the Frail Elderly. Hip and Pelvis, 35(1), 54–61. https://doi.org/10.5371/hp.2023.35.1.54

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free