Calibration of force actuators on an adaptive secondary prototype

5Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

In the context of the Large Binocular Telescope project, we present the results of force actuator calibrations performed on an adaptive secondary prototype called P45, a thin deformable glass with magnets glued onto its back. Electromagnetic actuators, controlled in a closed loop with a system of internal metrology based on capacitive sensors, continuously deform its shape to correct the distortions of the wavefront. Calibrations of the force actuators are needed because of the differences between driven forces and measured forces. We describe the calibration procedures and the results, obtained with errors of less than 1.5%. ©2008 Optical Society of America.

Cite

CITATION STYLE

APA

Ricci, D., Riccardi, A., & Zanotti, D. (2008). Calibration of force actuators on an adaptive secondary prototype. Applied Optics, 47(20), 3631–3636. https://doi.org/10.1364/AO.47.003631

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free