Improving the Sensitivity of Protein Quantification by Immunoaffinity Liquid Chromatography─Triple Quadrupole Mass Spectrometry Using an Iterative Transition Summing Technique

6Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The desire to reach ever-diminishing lower limits of quantification (LLOQ) to probe changes in low abundance protein targets has led to enormous progress in sample preparation and liquid chromatography-tandem mass spectrometry (LC-MS/MS) instrumentation. To maximize signal and reduce noise, many approaches have been employed, including specific immunoaffinity (IA) enrichment and reducing the LC flow to the nanoflow (nLC) level; however, additional sensitivity gains may still be required. Recently, a technique termed “echo summing” has been described for small-molecular-weight analytes on a triple quadrupole (QqQ) MS where multiple iterations of the same, single selected reaction monitoring (SRM) transition are collected, summed, and integrated, yielding significant analyte dependent signal-to-noise (S/N) improvements. Herein, the direct applicability of echo summing to protein quantification by sequential IA combined with nLC-MS/MS (IA-nLC-MS/MS) is described for a beta nerve growth factor (NGF) and a soluble asialoglycoprotein receptor (sASGPR) assay from human serum. Five iterations of echo summing outperformed traditional collection in relative average accuracy (−1.5 ± 7.7 vs −41.7 ± 10.7% bias) and precision (7.8 vs 18.4% coefficient of variation (CV)) of the low-end quality control (QC) sample (N = 4) for NGF and improved functional sensitivity of serially diluted serum QC samples (N = 5 each population) approximately 2-fold (1.96 and 2.00-fold) for two peptides of sASGPR. Echo summing also extended the minimum quantifiable QC level for sASGPR 4-fold lower. Similar gains are believed to be achievable for most protein IA-nLC-MS/MS assays.

Cite

CITATION STYLE

APA

Johnson, J. S., Palandra, J., Psychogios, N., Walsh, J. M., & Neubert, H. (2024). Improving the Sensitivity of Protein Quantification by Immunoaffinity Liquid Chromatography─Triple Quadrupole Mass Spectrometry Using an Iterative Transition Summing Technique. Analytical Chemistry, 96(36), 14326–14331. https://doi.org/10.1021/acs.analchem.3c04598

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley