Prospective evaluation of adhesion formation and shrinkage of intra-abdominal prosthetics in a rabbit model

74Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Laparoscopic ventral hernia repair requires an intraperitoneal prosthetic; however, these materials are not without consequences. We evaluated host reaction to intraperitoneal placement of various prosthetics and the functional outcomes in an animal model. Mesh (n = 15 per mesh type) was implanted on intact peritoneum in New Zealand white rabbits. The mesh types included ePTFE (DualMesh®), ePTFE and polypropylene (Composix®), polypropylene and oxidized regenerated cellulose (Proceed®), and polypropylene (Marlex®). Adhesion formation was evaluated at 1, 4, 8, and 16 weeks using 2-mm mini-laparoscopy. Adhesion area, adhesion tenacity, prosthetic shrinkage, and compliance were evaluated after mesh explantation at 16 weeks. DualMesh® had significantly less adhesions than Proceed®, Composix®, or Marlex® at 1, 4, 8, and 16 weeks (P < 0.0001). Marlex® had significantly more adhesions than other meshes at each time point (P < 0.0001). There were no statistically significant differences in adhesions between Proceed® and Composix® meshes. After mesh explantation, the mean area of adhesions for Proceed® (4.6%) was less than for Marlex® (21.7%; P = 0.001). The adhesions to Marlex® were statistically more tenacious than the DualMesh® and Composix® groups. Overall prosthetic shrinkage was statistically greater for DualMesh® (34.7%) than for the remaining mesh types (P < 0.01). Mesh compliance was similar between the groups. Prosthetic materials demonstrate a wide variety of characteristics when placed inside the abdomen. Marlex® formed more adhesions with greater tenacity than the other mesh types. DualMesh® resulted in minimal adhesions, but it shrank more than the other mesh types. Each prosthetic generates a varied host reaction. Better understanding of these reactions can allow a suitable prosthetic to be chosen for a given patient in clinical practice.

Cite

CITATION STYLE

APA

Harrell, A. G., Novitsky, Y. W., Peindl, R. D., Cobb, W. S., Austin, C. E., Cristiano, J. A., … Heniford, B. T. (2006). Prospective evaluation of adhesion formation and shrinkage of intra-abdominal prosthetics in a rabbit model. American Surgeon, 72(9), 808–813. https://doi.org/10.1177/000313480607200908

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free