Distortion corrected tomographic near-eye displays using light field optimization

  • Lee S
  • Lee S
  • Kim D
  • et al.
2Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Several multifocal displays have been proposed to provide accurate accommodation cues. However, multifocal displays have an undesirable feature, which is especially emphasized in near-eye displays configuration, that the field of views (FOVs) of the virtual planes change over depth. We demonstrate that this change in FOV causes image distortions, which reduces overall image quality, and depth perception error due to the variation of image sizes according to depths. Here, we introduce a light field optimization technique to compensate for magnification variations among the focal planes. Our approach alleviates image distortions, especially noticeable in the contents with large depth discontinuity, and reconstructs the image size to precise depths, while maintaining a specific tolerance length for the target eye relief. To verify the feasibility of the algorithm, we employ this optimization method for the tomographic near-eye display system to acquire the optimal image and backlight sequences for a volumetric scene. In general, we confirm that the structural similarity index measure of reconstructed images against ground truth increases by 20% when the eye relief is 15 mm, and the accommodation cue is appropriately stimulated at the target depth with our proposed method.

Cite

CITATION STYLE

APA

Lee, S., Lee, S., Kim, D., & Lee, B. (2021). Distortion corrected tomographic near-eye displays using light field optimization. Optics Express, 29(17), 27573. https://doi.org/10.1364/oe.435755

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free