Efficacy of Escherichia coli-derived recombinant human bone morphogenetic protein-2 in posterolateral lumbar fusion: an open, active-controlled, randomized, multicenter trial

36Citations
Citations of this article
72Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background Context The efficacy and safety of recombinant human bone morphogenetic protein-2 (rhBMP-2) as a bone graft substitute in spinal fusion has been widely researched. However, no study of the efficacy and safety of Escherichia coli-derived rhBMP-2 (E.BMP-2) with a hydroxyapatite (HA) carrier has been proposed. Purpose This study aimed to compare the efficacy and safety of fusion materials between E.BMP-2 and autogenous iliac bone graft in posterolateral fusion (PLF). Study Design/Setting An open, active-controlled, randomized, multicenter trial was carried out. Patient Sample This study included 93 patients who underwent single-level lumbar or lumbosacral PLF. Outcome Measures The primary outcome measure was computed tomography (CT)-based fusion rate at 12 and 24 weeks. Secondary outcome measures were fusion grade by radiographs and CT at 12 and 24 weeks and changes in Oswestry Disability Index (ODI), Short Form-36 (SF-36) Health Survey, and visual analogue scale (VAS). Methods Patients who underwent 1-level PLF (between L1 and S1) for severe spinal stenosis or grade 1 spondylolisthesis were randomized to receive E.BMP-2 with an HA carrier (E.BMP-2 group) or autogenous iliac bone graft (AIBG group). Thin-section CT (<2 mm), VAS, ODI, and SF-36 were obtained pre- and postoperatively at 12 and 24 weeks. Outcome measures were compared between the groups. Results A total of 100 patients were enrolled in this trial. Among them, 93 patients underwent planned surgery. Preoperative demographic and clinical data showed no difference between groups. CT-based fusion rates were 100.0% (41/41) for the E.BMP-2 group and 90.2% (46/51) for the AIBG group (p=.062) at 12 weeks and 100.0% (41/41) and 94.1% (48/51) (p=.251) at 24 weeks, respectively. Fusion grade based on radiographs and CT showed non-inferiority of the E.BMP-2 group compared with the AIBG group. All clinical parameters improved postoperatively. However, there was no difference in changes in VAS, ODI, or SF-36 between the groups. No serious adverse event related to E.BMP-2 was found. Conclusions The fusion rate of E.BMP-2 was comparable with that of AIBG following PLF. Good clinical efficacy and safety of E.BMP-2 in spinal fusion were also revealed. It was also suggested that HA shows suitability as a carrier for E.BMP-2. Thus, E.BMP-2 with an HA carrier can be an alternative bone graft material in spinal fusion.

Cite

CITATION STYLE

APA

Cho, J. H., Lee, J. H., Yeom, J. S., Chang, B. S., Yang, J. J., Koo, K. H., … Han, J. (2017). Efficacy of Escherichia coli-derived recombinant human bone morphogenetic protein-2 in posterolateral lumbar fusion: an open, active-controlled, randomized, multicenter trial. Spine Journal, 17(12), 1866–1874. https://doi.org/10.1016/j.spinee.2017.06.023

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free