Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model

125Citations
Citations of this article
70Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The purpose of this study was to develop and test a phantom model based on actual total hip replacement (THR) components to simulate the true penetration of the femoral head resulting from polyethylene wear. This model was used to study both the accuracy and the precision of radiostereometric analysis, RSA, in measuring wear. We also used this model to evaluate optimum tantalum bead configuration for this particular cup design when used in a clinical setting. 'A physical model of a total hip replacement (a phantom) was constructed which could simulate progressive, three-dimensional (3-D) penetration of the femoral head into the polyethylene component of a THR. Using a coordinate measuring machine (CMM) the positioning of the femoral head using the phantom was measured to be accurate to within 7 μm. The accuracy and precision of an RSA analysis system was determined from five repeat examinations of the phantom using various experimental set-ups of the phantom. The accuracy of the radiostereometric analysis, in this optimal experimental set-up studied was 33 μm for the medial direction, 22 μm for the superior direction, 86 μm for the posterior direction and 55 μm for the resultant 3-D vector length. The corresponding precision at the 95% confidence interval of the test results for repositioning the phantom five times, measured 8.4 μm for the medial direction, 5.5 μm for the superior direction, 16.0 μm for the posterior direction, and 13.5 μm for the resultant 3-D vector length. This in vitro model is proposed as a useful tool for developing a standard for the evaluation of radiostereometric and other radiographic methods used to measure in vivo wear. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.

Cite

CITATION STYLE

APA

Bragdon, C. R., Malchau, H., Yuan, X., Perinchief, R., Kärrholm, J., Börlin, N., … Harris, W. H. (2002). Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model. Journal of Orthopaedic Research, 20(4), 688–695. https://doi.org/10.1016/S0736-0266(01)00171-1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free