Noncontact Acoustic Micro-Tapping Optical Coherence Elastography for Quantification of Corneal Anisotropic Elasticity: In Vivo Rabbit Study

7Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

Purpose: The purpose of this study was to demonstrate accurate measurement of corneal elastic moduli in vivo with noncontact and noninvasive optical coherence elastography. Methods: Elastic properties (in-plane Young’s modulus, E, and both in-plane, μ, and out-of-plane, G, shear moduli) of rabbit cornea were quantified in vivo using noncontact dynamic acoustic micro-tapping optical coherence elastography (AμT-OCE). The intraocular pressure (IOP)-dependence of measured mechanical properties was explored in extracted whole globes following in vivo measurement. A nearly incom-pressible transverse isotropic (NITI) model was used to reconstruct moduli from AμT-OCE data. Independently, cornea elastic moduli were also measured ex vivo with traditional, destructive mechanical tests (tensile extensometry and shear rheometry). Results: Our study demonstrates strong anisotropy of corneal elasticity in rabbits. The in-plane Young’s modulus, computed as E = 3μ, was in the range of 20 MPa to 44 MPa, whereas the out-of-plane shear modulus was in the range of 34 kPa to 261 kPa. Both pressure-dependent ex vivo OCE and destructive mechanical tests performed on the same samples within an hour of euthanasia strongly support the results of AμT-OCE measurements. Conclusions: Noncontact AμT-OCE can noninvasively quantify cornea anisotropic elastic properties in vivo. Translational Relevance: As optical coherence tomography (OCT) is broadly accepted in ophthalmology, these results suggest the potential for rapid translation of AμT-OCE into clinical practice. In addition, AμT-OCE can likely improve diagnostic criteria of ectatic corneal diseases, leading to early diagnosis, reduced complications, customized surgical treatment, and personalized biomechanical models of the eye.

Cite

CITATION STYLE

APA

Kirby, M. A., Regnault, G., Pelivanov, I., O’donnell, M., Wang, R. K., & Shen, T. T. (2023). Noncontact Acoustic Micro-Tapping Optical Coherence Elastography for Quantification of Corneal Anisotropic Elasticity: In Vivo Rabbit Study. Translational Vision Science and Technology, 12(3). https://doi.org/10.1167/tvst.12.3.15

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free