Abstract
Background: Early screening and diagnosis of radiation-induced heart disease (RIHD) is difficult in patients with chest radiation exposure. sST-2 is involved in myocardial stress or injury. We evaluated the relationship between heart dose parameters and sST-2 changes in chest malignant tumor patients who received chest radiation. Methods: We prospectively collected thoracic malignancy cancer patients who had received chest radiotherapy. Heart dosimetry parameters were extracted from the treatment planning system. sST-2 was measured at baseline, the middle stage, and after radiotherapy (recorded as pre-ST-2, mid-ST-2, and post-ST-2). sST-2 change rate was calculated. Scatter plots showed the relationship between cardiac dose parameters and ST-2 change rate. Multiple regression was used to analyze the relationship between cardiac dose parameters and ST-2 change rate. Results: Totally, 60 patients were enrolled. The mean V5, V10, V20, V30, V40, and MHD was 60.93 ± 27.79%, 51.43 ± 25.44%, 39.17 ± 21.75%, 28.07 ± 17.15%,18.66 ± 12.18%, and 18.60 ± 8.63 Gy, respectively. The median M-LAD was 11.31 (IQR 3.33-18.76) Gy. The mean pre-ST-2, mid-ST-2, and post-ST-2 was 5.1 ± 3.8, 6.4 ± 3.9, and 7.6 ± 4.4, respectively. sST-2 was elevated with thoracic irradiation (P
Author supplied keywords
Cite
CITATION STYLE
Zeng, Z. min, Xu, P., Zhou, S., Du, H. yang, Jiang, X. liu, Cai, J., … Liu, A. wen. (2020). Positive association between heart dosimetry parameters and a novel cardiac biomarker, solubleST-2, in thoracic cancer chest radiation. Journal of Clinical Laboratory Analysis, 34(4). https://doi.org/10.1002/jcla.23150
Register to see more suggestions