Investigasi Lingkungan Termal Ruang Kelas Sekolah di Kota Pontianak

  • Lestari L
  • Alhamdani M
  • Nurhamsyah M
  • et al.
N/ACitations
Citations of this article
20Readers
Mendeley users who have this article in their library.

Abstract

The research of the thermal environment of the school building is useful for determining the design strategy of a thermally comfortable school building. This research method is based on field measurements. A total of 8 classrooms from 4 public school buildings in Pontianak City with different characteristics of opening directions, orientations, and floor locations were selected in this study. The results showed that the air temperature and humidity in the classroom ranged between 26.9 o C-33.5 o C and 74.5%-84.2%. The average air velocity in the classroom is 0.24m/s. The globe temperature is higher than the air temperature with an average difference of 7.7 o C. Protection against solar radiation and increased air velocity can be potential design strategies to achieve thermal comfort in classrooms.

Cite

CITATION STYLE

APA

Lestari, L., Alhamdani, M. R., Nurhamsyah, M., Muazir, S., & Rudiyono, R. (2022). Investigasi Lingkungan Termal Ruang Kelas Sekolah di Kota Pontianak. ARSITEKTURA, 20(2), 193. https://doi.org/10.20961/arst.v20i2.56058

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley