Technology for automated, rapid, and quantitative PCR or reverse transcription-PCR clinical testing

110Citations
Citations of this article
142Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: PCR-based assays can improve clinical care, but they remain technically demanding and labor-intensive. We describe a new instrument, the GeneXpert®, that performs automated nucleic acid isolation, reverse transcription, and fluorescence-based quantitative FCR in ∼35 min. Methods: Yield and integrity of RNA isolated on the GeneXpert were compared with Qiagen-based extraction for parallel samples (5-μm frozen tissue sections). The reproducibility of automated RNA isolation, reverse transcription, and quantitative PCR was determined by replicate (n = 10) analysis of 10 tissues, using duplex (target and endogenous control) reverse transcription-PCR reactions for two gene combinations. The GeneXpert was then used to perform rapid analysis of lymph nodes from melanoma, breast cancer, and lung cancer patients and analysis of melanoma metastatic to the lung, primary lung adenocarcinoma, and healthy lung tissue. Results: On the GeneXpert, RNA was recovered in slightly over 6 min, and the yield was ∼70% of that from parallel Qiagen reactions. The RNA integrity was comparable to that of Qiagen-isolateci RNA as determined by gel electrophoresis. For the melanoma samples, the 95% prediction interval for the ΔCt for a new measurement was ±1.54 cycles, and for breast cancer samples, the interval for a newly observed ΔCt was ±1.40 cycles. GeneXpert assays successfully detected the presence of metastatic melanoma, breast cancer, and lung cancer in lymph nodes and also differentiated among metastatic melanoma, lung adenocarcinoma, and healthy lung. Conclusions: RNA yield and integrity on the GeneXpert are comparable to benchtop methods. Reproducibility of the GeneXpert data is similar to that seen with manual methods in our hands but may need improvement for some applications. The GeneXpert can perform RNA isolation, reverse transcription, and quantitative PCR un ∼35 min and could therefore be used for intraoperative testing when applicable. © 2005 American Association for Clinical Chemistry.

Cite

CITATION STYLE

APA

Raja, S., Ching, J., Xi, L., Hughes, S. J., Chang, R., Wong, W., … Godfrey, T. E. (2005). Technology for automated, rapid, and quantitative PCR or reverse transcription-PCR clinical testing. Clinical Chemistry, 51(5), 882–890. https://doi.org/10.1373/clinchem.2004.046474

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free