Effect of haemorrhage on plasma propofol concentrations in a patient undergoing orthotopic liver transplantation

7Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

We report a patient who underwent repeat orthotopic liver transplantation complicated by intraoperative blood loss of more than 59 litre. During liver transplantation, a constant rate propofol infusion was given and plasma samples were obtained throughout the procedure for propofol assay. Before the anhepatic phase of the procedure, plasma propofol concentrations reached a plateau at 1 μg ml-1, and these concentrations were consistent with those predicted using a pharmacokinetic model. During the anhepatic phase of surgery, serum propofol concentrations increased progressively and exceeded those predicted by the pharmacokinetic model. Large intravascular fluid shifts associated with blood loss and subsequent blood replacement influenced plasma propofol concentrations observed in this patient.

Cite

CITATION STYLE

APA

Turner, R. J., Kam, P. C. A., Ramzan, I., & Santilli, M. B. (1999). Effect of haemorrhage on plasma propofol concentrations in a patient undergoing orthotopic liver transplantation. British Journal of Anaesthesia, 83(2), 346–348. https://doi.org/10.1093/bja/83.2.346