Validated chromatographic methods for concurrent determination of atorvastatin and perindopril

7Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Two simple, selective, precise, and accurate chromatographic methods, namely reversed-phase highperformance liquid chromatography (RP-HPLC) method and High-performance thin-layer chromatography (HPTLC), were developed and validated for the simultaneous determination of Atorvastatin (ATO) and Perindopril (PER). The developed HPTLC method was used for the separation and quantitation of the studied drugs on silica gel 60F254 TLC plates. Dichloromethane: Methanol: Ethyl acetate: Glacial acetic acid (6:2:2:0.1, v/v/v/v) was used as a developing system and the separated bands were UV-scanned at 221 nm. Linear relationships were obtained in the range of 800 – 4800 ng/band for Atorvastatin and 200 – 1200 ng/band for Perindopril with a regression coefficient greater than 0.999. The Rf value of the drug was found to be 0.70 ± 0.02 and 0.39 ± 0.03 for Atorvastatin and Perindopril respectively. The developed RP-HPLC depended on chromatographic separation of the studied drugs on a C18 column using Acetonitrile: Methanol: Potassium dihydrogen orthophosphate (pH 3 adjusted with orthophosphoric acid) ((40:10:50), v/v/v) as a mobile phase delivered at a constant flow rate of 1 mL/min with UV detection at 240 nm. The calibration curves were linear (r2 > 0.999) over the concentration range 20-100 µg/mL for Atorvastatin and 10-50µg/mL for Perindopril. The average retention times for Atorvastatin and Perindopril were 3.42 and 8.92 min, respectively. Factors affecting the developed methods have been studied and optimized. Further, methods validation has been carried out according to ICH guidelines. The proposed methods were successfully applied for the determination of the studied drug simultaneously in bulk and synthetic mixture qualitatively and quantitatively. Statistical analysis by the F test showed no significant difference between the results obtained by the two methods. The uncertainty measurement was also carried out for the quantification of both components. The proposed HPTLC method proved to be more sensitive, while the HPLC gave more reproducible results and was time-saving.

Author supplied keywords

Cite

CITATION STYLE

APA

Patel, S., Patel, C., Surati, J., Akabari, A., & Shah, K. (2022). Validated chromatographic methods for concurrent determination of atorvastatin and perindopril. Journal of Chemical Metrology, 16(2), 111–124. https://doi.org/10.25135/jcm.72.2208.2545

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free