Predicting the difficulty of operative vaginal delivery by ultrasound measurement of fetal head station

14Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

Abstract

Background Clinical assessment of fetal head station is difficult and subjective; it is mandatory before attempting operative vaginal delivery. Objective The principal objective of our study was to assess whether measurement of the perineum-to-skull ultrasound distance was predictive of a difficult operative vaginal delivery. Secondary objectives included evaluation of the interobserver reproducibility of perineum-to-skull ultrasound distance and comparison of this measurement and digital examination in predicting a difficult operative delivery. Study Design This was a prospective cohort study including all cases of operative vaginal deliveries in singleton pregnancies in cephalic presentation >34 weeks’ gestation, from 2012 through 2015. All data were entered prospectively in a medical record system specially devised to meet the requirements of this study. Results Of the 659 patients in whom perineum-to-skull ultrasound distance was measured prior to operative vaginal delivery, 120 (18%) met the composite criterion for a difficult extraction. Perineum-to-skull ultrasound distance measurement of ≥40 mm was significantly associated with the occurrence of a difficult extraction based on the composite criterion, after adjustment for parity, presentation type, and fetal macrosomia (odds ratio, 2.38; 95% confidence interval, 1.51–3.74; P = .0002). The intraclass correlation coefficient between the perineum-to-skull ultrasound distance measured by the first operator and that measured by the second operator was 0.96 (95% confidence interval, 0.95–0.97; P <.0001). Based on the receiver operating characteristic curve analyses, perineum-to-skull ultrasound distance was a more accurate predictor of difficult operative delivery than digital vaginal examination (P =.036). Conclusion Measurement of the perineum-fetal skull ultrasound distance is a reproducible and predictive index of the difficulty of instrumental extraction. Ultrasound is a useful supplementary tool to the usual clinical findings.

Cite

CITATION STYLE

APA

Kasbaoui, S., Séverac, F., Aïssi, G., Gaudineau, A., Lecointre, L., Akladios, C., … Sananès, N. (2017). Predicting the difficulty of operative vaginal delivery by ultrasound measurement of fetal head station. In American Journal of Obstetrics and Gynecology (Vol. 216, pp. 507.e1-507.e9). Mosby Inc. https://doi.org/10.1016/j.ajog.2017.01.007

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free