Universal Capacitive Sensors and Transducers Interface

6Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

The universal interfacing integrated circuit for direct capacitance-to-digital and capacitance-to-frequency (period, time interval)-to-digital conversion suitable for various capacitive sensing elements is newly presented in the paper. Measurement results havesuccessfully verified the functions and performance of the proposed circuit. The capacitance range is from 50 pF to 100 μF. Theworst case relative error for reported results is not more than ± 0.7 %. Any capacitance-to-frequency converters can be also connectedto the designed universal sensors and transducers interfacing circuit. The relative error for the further frequency-to-digitalconversion is constant in the whole frequency range and not exceeds ± 0.0005 %. © 2009.

Cite

CITATION STYLE

APA

Yurish, S. Y. (2009). Universal Capacitive Sensors and Transducers Interface. In Procedia Chemistry (Vol. 1, pp. 441–444). https://doi.org/10.1016/j.proche.2009.07.110