2D and 3D High Frame Rate Imaging with Limited Diffraction Beams

214Citations
Citations of this article
101Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A new 2D (two-dimensional) and 3D (three-dimensional) pulse-echo imaging method (Fourier method) has been developed with limited diffraction beams. In this method, a plane wave pulse (broadband) is used to transmit and limited diffraction beams of different parameters are used to receive. Signals received are processed to obtain spatial Fourier transform of object functions and images are constructed with an inverse Fourier transform. Because only one transmission is required to construct images, this method may achieve a high frame rate (up to 3750 frames/s for biological soft tissues at a depth of 200 mm). To demonstrate the efficacy of the method, both 2D C-mode and 3D images have been simulated using conditions that are typical for medical ultrasound. Results show that images of high resolutions (about 6 wavelengths at 200 mm) and low sidelobes (around -60 dB) can be constructed over a large depth of interest (30 to 200 mm) with a 50 mm diameter aperture. Experiments with the new method have also been carried out. 2D B-mode images have been constructed with conventional linear arrays. In the experiment, an ATS 539 tissue-equivalent phantom and two linear arrays were used. The first array had a center frequency of 2.25 MHz, dimension of 18.288 mm × 12.192 mm, and 48 elements. The second had a center frequency of 2.5 MHz, 38.4 mm × 10 mm in dimension, and 64 elements. Images of different fields of views were constructed from RF data acquired with these arrays using both the new and conventional dynamic focusing (delay-and-sum) methods. Results show that qualities of images constructed are almost identical with the two methods in terms of sidelobes, contrast, and lateral and axial resolutions. Phase aberration has also been assessed for the two methods, and results show that its influence is about the same on both methods. In addition, a practical imaging system to implement the new method is suggested and potential applications of the method are discussed. © 1997 IEEE.

Cite

CITATION STYLE

APA

Lu, J. Y. (1997). 2D and 3D High Frame Rate Imaging with Limited Diffraction Beams. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 44(4), 839–856. https://doi.org/10.1109/58.655200

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free