Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty

75Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: First-generation cementless modular cups reproducibly achieved fixation to bone but were associated with unacceptable rates of pelvic osteolysis and mechanical failure. Consequently, second-generation cups were developed with shells that had a limited number of holes (or no holes) as well as improved locking mechanisms, a polished inner surface, and increased conformity with the liner. The purpose of the present study was to evaluate the clinical and radiographic results associated with the use of a second-generation acetabular component for primary total hip arthroplasty. Methods: Two hundred and ninety-seven patients underwent 335 consecutive primary total hip arthroplasties that were performed by a single surgeon with a second-generation modular acetabular component. All cups were implanted with a press-fit technique. Ten patients were lost to follow-up, and sixteen died from unrelated causes. The remaining 271 patients (308 hips) were followed clinically (with the Hospital for Special Surgery hip-scoring system) and radiographically for four to seven years. Results: One cup was revised because of aseptic loosening. There were seven additional revisions: five were performed because of aseptic loosening of the stem with a well-fixed cup, and two were performed because of deep infection. Among the 271 patients who were alive at the time of the last follow-up, 266 (98%) had retention of the cup and 264 (97%) had retention of both components with a good or excellent clinical result. In the group of 229 patients (262 hips) with complete radiographic follow-up, 259 cups were well fixed and the average wear rate (for the 246 hips for which this rate could be calculated) was 0.09 mm/yr. Osteolysis was detected in twelve hips (5%) and was associated with male gender (p = 0.001) and the annual wear rate (p = 0.004). The extent of calcar resorption was also associated with the annual wear rate (p < 0.001). Conclusions: This second-generation acetabular cup design predictably achieved bone fixation and was associated with low rates of revision for loosening and osteolysis after intermediate-term follow-up. Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]).

Cite

CITATION STYLE

APA

González Della Valle, A., Zoppi, A., Peterson, M. G. E., & Salvati, E. A. (2004). Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty. Journal of Bone and Joint Surgery, 86(9), 1998–2004. https://doi.org/10.2106/00004623-200409000-00019

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free