Commissioning of the ATLAS thermal-hydraulic integral test facility

55Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.
Get full text

Abstract

KAERI recently constructed a new thermal-hydraulic integral test facility for advanced pressurized water reactors (PWRs) - ATLAS. The ATLAS facility has the following characteristics: (a) 1/2-height&length, 1/288-volume, and full pressure simulation of APR1400, (b) maintaining a geometrical similarity with APR1400 including 2(hot legs) × 4(cold legs) reactor coolant loops, direct vessel injection (DVI) of emergency core cooling water, integrated annular downcomer, etc., (c) incorporation of specific design characteristics of OPR1000 such as cold leg injection and low-pressure safety injection pumps, (d) maximum 10% of the scaled nominal core power. The ATLAS will mainly be used to simulate various accident and transient scenarios for evolutionary PWRs, OPR1000 and APR1400: the simulation capability of broad scenarios including the reflood phase of a large-break loss-of-coolant accident (LOCA), small-break LOCA scenarios including DVI line breaks, a steam generator tube rupture, a main steam line break, a feed line break, a mid-loop operation, etc. The ATLAS is now in operation after an extensive series of commissioning tests in 2006. © 2008 Elsevier Ltd. All rights reserved.

Cite

CITATION STYLE

APA

Kim, Y. S., Choi, K. Y., Park, H. S., Cho, S., Kim, B. D., Choi, N. H., & Baek, W. P. (2008). Commissioning of the ATLAS thermal-hydraulic integral test facility. Annals of Nuclear Energy, 35(10), 1791–1799. https://doi.org/10.1016/j.anucene.2008.05.010

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free