Comparison of characteristics of ECT probes in detecting defects

  • Mun H
  • Kim C
  • 5

    Readers

    Mendeley users who have this article in their library.
  • 0

    Citations

    Citations of this article.

Abstract

In this paper, the characteristics of a defective elliptical aluminum plate was analyzed by three different eddy current testing probes; T/R, T/T, and Impedance probes. The analysis was done by 3D finite element method, and the impedance change of real and imaginary voltage values were analyzed.