Cyclic Behavior of HPFRCC Coupling Beams with Bundled Diagonal Bars

6Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Coupled shear walls are efficient in resisting lateral forces induced by winds and earthquakes. However, it is difficult to construct coupled shear walls particularly because current design codes require complex reinforcing details within coupling beams. The objective of this study was to develop simple reinforcement details for diagonally reinforced coupling beams; reducing transverse steel by use of high-performance fiber-reinforced cementitious composites (HPFRCCs) and bundling diagonal bars are explored. Four coupling beam specimens with length-to-depth aspect ratios of 2.0 or 3.5 were fabricated and tested under cyclic lateral displacements. The test results revealed that HPFRCC coupling beams with bundled diagonal bars and widely spaced transverse reinforcement (one-half the amount of reinforcement required by current seismic codes) exhibited excellent seismic performance compared with ordinary concrete coupling beams having code-required distributed diagonal reinforcement and transverse reinforcement.

Cite

CITATION STYLE

APA

Han, S. W., Kang, J. W., Jee, H. W., Shin, M., & Lee, K. (2018). Cyclic Behavior of HPFRCC Coupling Beams with Bundled Diagonal Bars. International Journal of Concrete Structures and Materials, 12(1). https://doi.org/10.1186/s40069-018-0271-6