Evaluation of mda instant working level meters

  • Holub R
  • Droullard R
  • Davis T
 et al. 
  • 3

    Readers

    Mendeley users who have this article in their library.
  • 1

    Citations

    Citations of this article.

Abstract

The U.S. Bureau of Mines and the Mine Safety and Health Administration have evaluated, for accuracy and reliability, a commercially available Instant Working Level Meter (IWLM) used by the mining industry to measure short-lived 222Rn-progeny concentrations. Six evaluation parameters were determined experimentally. These included two alpha and two beta detector efficiencies for the short-lived 222Rn progeny and two internal conversion factors. The experimental procedure detailing the evaluation technique is described in the paper. The measuring accuracy of 13 instruments is as follows: average inherent uncertainty (at least 68% confidence interval) is +/- 18%; for counting statistics and rounding at 0.10 WL (2.1 microJ m-3), coefficients of variation range from +/- 15% at low gamma flux backgrounds to +/- 50% at gamma flux backgrounds of 0.39 microC kg-1 h-1 (1.5 mR h-1). All parameters were derived theoretically and measured experimentally. All tests were conducted at a sample flow rate of 2.5 L min-1. A sample air flow rate of 7.5 L min-1 can lower the counting statistics to more acceptable levels at 0.1 WL (2.1 microJ m-3).

Get free article suggestions today

Mendeley saves you time finding and organizing research

Sign up here
Already have an account ?Sign in

Find this document

Authors

  • Robert F. Holub

  • Robert F. Droullard

  • Ted H. Davis

  • Wade E. Cooper

  • James F. Stewart

Cite this document

Choose a citation style from the tabs below

Save time finding and organizing research with Mendeley

Sign up for free