Experimental determination of the radiation dose limit for cryocooled protein crystals

N/ACitations
Citations of this article
215Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Radiation damage to cryocooled protein crystals during x-ray structure determination has become an inherent part of macromolecular diffraction data collection at third-generation synchrotrons. Generally, radiation damage is an undesirable component of the experiment and can result in erroneous structural detail in the final model. The characterization of radiation damage thus has become an important area for structural biologists. The calculated dose limit of 2 × 107 Gy for the diffracting power of cryocooled protein crystals to drop by half has been experimentally evaluated at a third-generation synchrotron source. Successive data sets were collected from four holoferritin and three apoferritin crystals. The absorbed dose for each crystal was calculated by using the program RADDOSE after measurement of the incident photon flux and determination of the elemental crystal composition by microparticle-induced x-ray emission. Degradation in diffraction quality and specific structural changes induced by synchrotron radiation then could be compared directly with absorbed dose for different dose/dose rate regimes: a 10% lifetime decrease for a 10-fold dose rate increase was observed. Remarkable agreement both between different crystals of the same type and between apoferritin and holoferritin was observed for the dose required to reduce the diffracted intensity by half (D1/2). From these measurements, a dose limit of D1/2 = 4.3 (±0.3) × 107 Gy was obtained. However, by considering other data quality indicators, an intensity reduction to IIn2 = In2 × I0, corresponding to an absorbed dose of 3.0 × 107 Gy, is recommended as an appropriate dose limit for typical macromolecular crystallography experiments. © 2006 by The National Academy of Sciences of the USA.

Cite

CITATION STYLE

APA

Owen, R. L., Rudiño-Piñera, E., & Garman, E. F. (2006). Experimental determination of the radiation dose limit for cryocooled protein crystals. Proceedings of the National Academy of Sciences of the United States of America, 103(13), 4912–4917. https://doi.org/10.1073/pnas.0600973103

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free